SMS Controller Alarm
GSM 3G 4G SMS Remote Controller Alarm(2DIN+2DO+USB)
Item No.: S130
S130 is a cost-effective Cellular SMS Controller. The SMS controller features digital inputs, relay outputs, it can be used in places which require turning ON/OFF your system, remotely control machines and equipment with a text message.
Introduction
Features
Specifications
Download
Applications
S130 is a cost-effective Cellular SMS Controller. The SMS controller features 2 digital inputs, 2 relay outputs, it can be connected to various detectors, such as water level detectors, door sensors, infrared detectors, temperature detectors, humidity detectors, water immersion detectors, glass breakage detectors, shock detectors, motion detectors, and others.
The SMS Controller allows you to monitoring and controlling remotely by SMS. When any input triggered or recovery, will switch on the relay automatically, and send SMS immediately. This is very useful if you need protect your assets with low cost solution. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.
The SMS controller features powerful SMS functions, send a SMS to Arming, Disarming, Close relay, Open relay, Query device status, Set alarm verify time, etc.
Item | Specifications | |
DC Power Supply | Standard Adapter: DC 12V/1.5A | |
Power Consumption | Regular: 50mA; Max.:500mA | |
4G | L-E | GSM/EDGE:900,1800MHz WCDMA:B1,B5,B8 FDD-LTE:B1,B3,B5,B7,B8,B20 TDD-LTE:B38,B40,B41 |
L-AU | GSM/EDGE:850,900,1800MHz WCDMA:B1,B2,B5,B8 FDD-LTE:B1,B3,B4,B5,B7,B8,B28 TDD-LTE:B40 |
|
L-A | WCDMA:B2,B4,B5 FDD-LTE:B2,B4,B12 |
|
L-J | WCDMA:B1,B3,B8,B18,B19,B26 FDD:B2,B4,B12 TDD: B41 |
|
SIM Interface | Supporting 3V SIM Card | |
External Antenna | SMA Antenna interface, 50 Ohm | |
Digital Inputs | 2 channel, Dry contact, NC, NO, or EOL | |
Relay Outputs | 2 Relay Outputs, 7A@125VAC; 5A@250VAC; 20A@14VDC | |
Siren Output | 1 | |
Backup Battery | 3.7V 900mAH | |
Exterior Dimension | 70x88x30mm | |
Installation | 35mm standard DIN rail(Optional); Wall mount (Default) |
Description
S130 is a cost-effective Cellular SMS Controller. The SMS controller features 2 digital inputs, 2 relay outputs, it can be connected to various detectors, such as water level detectors, door sensors, infrared detectors, temperature detectors, humidity detectors, water immersion detectors, glass breakage detectors, shock detectors, motion detectors, and others.
The SMS Controller allows you to monitoring and controlling remotely by SMS. When any input triggered or recovery, will switch on the relay automatically, and send SMS immediately. This is very useful if you need protect your assets with low cost solution. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.
The SMS controller features powerful SMS functions, send a SMS to Arming, Disarming, Close relay, Open relay, Query device status, Set alarm verify time, etc.
introduction
Features
Specifications
Item | Specifications | |
DC Power Supply | Standard Adapter: DC 12V/1.5A | |
Power Consumption | Regular: 50mA; Max.:500mA | |
4G | L-E | GSM/EDGE:900,1800MHz WCDMA:B1,B5,B8 FDD-LTE:B1,B3,B5,B7,B8,B20 TDD-LTE:B38,B40,B41 |
L-AU | GSM/EDGE:850,900,1800MHz WCDMA:B1,B2,B5,B8 FDD-LTE:B1,B3,B4,B5,B7,B8,B28 TDD-LTE:B40 |
|
L-A | WCDMA:B2,B4,B5 FDD-LTE:B2,B4,B12 |
|
L-J | WCDMA:B1,B3,B8,B18,B19,B26 FDD:B2,B4,B12 TDD: B41 |
|
SIM Interface | Supporting 3V SIM Card | |
External Antenna | SMA Antenna interface, 50 Ohm | |
Digital Inputs | 2 channel, Dry contact, NC, NO, or EOL | |
Relay Outputs | 2 Relay Outputs, 7A@125VAC; 5A@250VAC; 20A@14VDC | |
Siren Output | 1 | |
Backup Battery | 3.7V 900mAH | |
Exterior Dimension | 70x88x30mm | |
Installation | 35mm standard DIN rail(Optional); Wall mount (Default) |